Pomiń, aby przejść do informacji o produkcie
1 z 7

Wholesale lifepo4 5KWH 51.2V 100ah wall mounted battery pack

Wholesale lifepo4 5KWH 51.2V 100ah wall mounted battery pack

Cena regularna $609.00 USD
Cena regularna $689.00 USD Cena promocyjna $609.00 USD
W promocji Wyprzedane
Koszt wysyłki obliczony przy realizacji zakupu.

Wholesale lifepo4 5KWH 51.2V 100ah wall mounted battery pack

Built in 16S 100A smart BMS, combatible with most of famous inverter as below:

deye, growatt, victron, sma, goodway, must.

Items

Specifications

Rated energy(kWh)

5.120KWh

Configuration

1P16S

Nominal Voltage(V)

51.2V

Working Voltage(V)

42V~58.4V

Nominal    Capacity(Ah)

100Ah

Rated charge/discharge

Current(A)

 

50A@25± 2

Maximum charging current

100A@25± 2

Maximum discharge current

100A @25± 2

Working    Temperature

0~40(Charge)    -20~40(Discharge)

Humidity(%)

5~80%

Altitude Limited(m)

0-3000m

Weight(Kg)

48Kg±3kg

Dimension(mm)

(600×(368)×(150)mm

Storage temperature and humidity

- 10~35(Within one month of storage) 

25± 2(Within three months of storage)

65%±20% RH

weight

48Kg±3kg

 

cycle life

4800 cycles @25

50A charge and discharge current 70% standard

capacity 90% DOD   

IP grade

IP20

Communication mode

CAN&RS485

 

Shipment from CHINA:

DDP: door to door, tax free.

Shipping time about 40-50 days.

EVE original grade A cells, support OEM.

Looking for distributors all over the world.

5.   Working mode

5.1 Charging mode

When a charger was detected, and the charger voltage is 0.5V+ more than the  battery voltage,  BMS will turn on the charging  MOSFET.And when the

charging  current  reaches  the  effective  charging  current  value,enters

charging mode.

5.2 Discharging mode

When a loads was detected, and the discharging current reaches the effective discharging current value, BMS enters discharging mode.

5.3 Standby mode

When the BMS not in charging mode, nor discharging mode, it enters standby mode.

5.4 Power off mode

The  BMS  enters  the  shutdown  mode  after  48  hours  of  normal  standby, battery triggering under voltage protection, key shutdown or external switch shutdown.

Wake-up conditions of shutdown mode:

1)  Charge activation

2)  48V voltage active

3) Press key to start

7.   Safety precautions

Do not  place the battery on flammable building materials.

Recommended to hang the battery on the vertical wall.

T h e temperature should b e between  10 and 30  to maintain the best operating state .

The   installation  site  should   be some free space around the battery to dissipate heat (as shown in the figure below), which is suitable for              installation on the concrete surface or other non-flammable surfaces.

 


Pokaż kompletne dane